宿州附近想过夜电话联系

National Service Hotline

400-039-9905

Hot products: High and low temperature test chamber Walking in high and low temperature damp heat Laboratory High and low temperature alternating test chamber High and low temperature shock test chamber High and low temperature damp heat test chamber

Manufacturer of high and low temperature test box

800L high and low temperature alternating test chamber

Source: this website published on: November 2, 2018 17:03:00 reading: 1009

Asli 800L high and low temperature alternating test chamber Try The structural design of the test system is advanced and reasonable Standard manufacturing process, beautiful appearance and easy maintenance. The main functional components are imported with international advanced level, which improves the safety and reliability of the products and ensures the users' long-term and high-frequency use requirements. The additional conditions required for the normal operation of the equipment have been equipped, and the buyer only needs to provide power, power and working environment to meet the requirements.

800L high and low temperature alternating test chamber Technical indicators:  

 800L high and low temperature alternating test chamber

Studio size: 650×750×600(mm)(W×H×D)  

Dimensions: About 1200X1850X1100(mm)(W×H×D)  

Temperature range: -40℃~+80℃  

Heating time: -40 ℃ ~ + 80 ℃ ≤ 20 minutes; cooling time: from + 80 ℃ to - 40 ℃ ≤ 20 minutes

Temperature fluctuation: ≤±0.5℃  

Temperature deviation: ≤±2℃  

Note: the above performance indexes are at the ambient temperature of 0 No load data were measured at ± 5 ℃.  

800L high and low temperature alternating test chamber implement /Meet the standard:

1. GB 10592.2-1989 technical conditions

2. Technical conditions of high temperature test chamber

3. Technical conditions of cryogenic test chamber

4. GB / t2423.1-2001 (iec68-2-1) test a low temperature test method

5. GB / t2423.2-2001 (iec68-2-2) test B high temperature test method

6. Gjb150.3-1986 high temperature test

7. Gjb150.4-1986 low temperature test

8. Gb2423.22 test method for temperature change


800L high and low temperature alternating test chamber structure

Temperature range: +100℃~+132℃

Humidity range: 100%

Temperature controller: using microcomputer LED display film button type PID temperature control instrument, temperature single point independent control, with multiple groups of PID control functions

Heating system: stainless steel fin heater .

Humidification system: electric heating surface evaporation mode The water outlet for cleaning is attached

Inner box material: Japanese mirror stainless steel( SUS#304).

Material of outer box: Japan electrostatic spraying technology( SUS#304).

Safety protection device: no fuse overload protector , compressor over-current overload protector, over temperature power-off protector, water shortage protection, heating humidifier dry burning protection, heating humidifier quick safety

Service voltage: 1Ф220V8A50HZ±10%  

Water requirement: RO reverse osmosis pure water or distilled water

Manufacturer of high and low temperature alternating test box   Price of high and low temperature alternating test box   Ranking of high and low temperature alternating test chambers   Principle of high and low temperature alternating test chamber

Maintenance of high and low temperature alternating test box   Maintenance of high and low temperature alternating test chamber   High and low temperature alternating test box brand   High and low temperature alternating test box equipment

800L high and low temperature alternating test chamber Introduction:  

Aisli 800L high and low temperature alternating test box It is designed and manufactured according to relevant national standards It is widely used in the high and low temperature test and rapid temperature change test of complete machine and parts of products in aviation, aerospace, ship, electrical, electronic and material industries. In order to evaluate the performance and quality of the sample.